SERVICES PROVIDED :
Overall Width (l/r) | 11 ft. 7 in. |
Overall Height (incl. Chimney) | 11 ft. 1 in.
|
Overall Depth (f/r) | 9 ft. 3 in. |
Total Weight (empty) | 12000 lb. |
Water Capacity | 950 gal. |
Forced Air Capacity | 100-3000 CFM |
Chimney Diameter | (4) 4 in. chimneys |
Max. Recommended Log Length | 8 ft. |
Firebox Width | 9 ft. |
Firebox Depth | 4 ft. (23 degree floor) |
Firebox Height | 4 ft. (23 degree floor) |
Volume of Firebox | 110 cu. ft. |
Firebox Door Size | 4 ft. X 9 ft. |
BTU/hr. @ 8 hr. Burn Cycle | 1.4-2.5 million |
Water Jacket Steel (gage) | 7 gal, A36 sheet |
Firebox Steel (gage) | .375 in., A36 sheet |
Opening Height | 50 in. |
Hook Ups | Rear Modular |
Total Heat Extraction Area | 192 sq. ft. |
Type of Fuel | Wood |
Electrical Supply | 115 V, 60 hz, 1 ph. Or 220 V, 60 hz, 1 ph. |
Hydraulic Oil Capacity | 2 gal. |
Lift Capacity | 24000 lb. |
Hydraulic Cylinders | (2) 2.5 in X 24 in. |
Auger Drive Leash | Low Speed Hi-tq. Hyd. Motor |
Overall Width (l/r) | 12 ft. 7 in. |
Overall Height (incl. Chimney) | 13 ft. 1 in.
|
Overall Depth (f/r) | 9 ft. 3 in. |
Total Weight (empty) | 14000 lb. |
Water Capacity | 1120 gal. |
Forced Air Capacity | 100-3000 CFM |
Chimney Diameter | (4) 4 in. chimneys |
Max. Recommended Log Length | 8 ft. |
Firebox Width | 10 ft. |
Firebox Depth | 6 ft. (23 degree floor) |
Firebox Height | 6 ft. (23 degree floor) |
Volume of Firebox | 225 cu. ft. |
Firebox Door Size | 4 ft. X 10 ft. |
BTU/hr. @ 8 hr. Burn Cycle | 1.4-2.5 million |
Water Jacket Steel (gage) | 7 gal, A36 sheet |
Firebox Steel (gage) | .375 in., A36 sheet |
Opening Height | 70 in. |
Hook Ups | Rear Modular |
Total Heat Extraction Area | 325 sq. ft. |
Type of Fuel | Wood |
Electrical Supply | . Or 220 V, 60 hz, 1 ph. |
Hydraulic Oil Capacity | 2 gal. |
Lift Capacity | 24000 lb. |
Hydraulic Cylinders | (2) 2.5 in X 24 in. |
Auger Drive Leash | Low Speed Hi-tq. Hyd. Motor |
Our new controls give us state of of the art control over the wood fuel at all times during the burn cycle allowing us to control exhaust temperature plus or minus 1 degree f ,sending out email notifications for any curcumstance including refuel all parameters can be viewed and changed from any computer or smart phone at all times , this controller has dramaticly reduced the amount of fuel needed to mantain high output and gives us the ability to service our customers online via ip adress